@@ -39,12 +39,12 @@ extension AutosensSettings {
|
|
|
VStack(alignment: .leading, spacing: 5) {
|
|
|
Text("What it Adjusts").bold()
|
|
|
Text(
|
|
|
- "Autosens modifies Insulin Sensitivity Factor (ISF), basal rates, and target blood sugar levels. It doesn’t account for carbs but adjusts for insulin effectiveness based on patterns in your glucose data."
|
|
|
+ "Autosens modifies Insulin Sensitivity Factor (ISF), basal rates, and target glucose. It doesn’t account for carbs but adjusts for insulin effectiveness based on patterns in your glucose data."
|
|
|
)
|
|
|
}
|
|
|
|
|
|
VStack(alignment: .leading, spacing: 5) {
|
|
|
- Text("Key Limitations").bold()
|
|
|
+ Text("Safety").bold()
|
|
|
Text(
|
|
|
"Autosens has safety limits determined by your Autosens Max and Autosens Min settings. These settings prevent over-adjusting."
|
|
|
)
|
|
|
@@ -140,18 +140,18 @@ extension AutosensSettings {
|
|
|
units: state.units,
|
|
|
type: .decimal("autosensMax"),
|
|
|
label: String(localized: "Autosens Max", comment: "Autosens Max"),
|
|
|
- miniHint: String(localized: "Upper limit of the Autosens Ratio."),
|
|
|
+ miniHint: String(localized: "Upper limit of the Sensitivity Ratio."),
|
|
|
verboseHint:
|
|
|
VStack(alignment: .leading, spacing: 10) {
|
|
|
Text("Default: 120%").bold()
|
|
|
Text(
|
|
|
- "Autosens Max sets the maximum Autosens Ratio used by Autosens, Dynamic ISF, and Sigmoid Formula."
|
|
|
+ "Autosens Max sets the maximum Sensitivity Ratio used by Autosens, Dynamic ISF, and Sigmoid Formula."
|
|
|
)
|
|
|
Text(
|
|
|
- "The Autosens Ratio is used to calculate the amount of adjustment needed to basal rates, ISF, and CR."
|
|
|
+ "The Sensitivity Ratio is used to calculate the amount of adjustment needed to basal rates and ISF."
|
|
|
)
|
|
|
Text(
|
|
|
- "Tip: Increasing this value allows automatic adjustments of basal rates to be higher, ISF to be lower, and CR to be lower."
|
|
|
+ "Tip: Increasing this value allows automatic adjustments of basal rates to be higher and ISF to be lower."
|
|
|
)
|
|
|
},
|
|
|
headerText: String(localized: "Glucose Deviations Algorithm")
|
|
|
@@ -171,18 +171,18 @@ extension AutosensSettings {
|
|
|
units: state.units,
|
|
|
type: .decimal("autosensMin"),
|
|
|
label: String(localized: "Autosens Min", comment: "Autosens Min"),
|
|
|
- miniHint: String(localized: "Lower limit of the Autosens Ratio."),
|
|
|
+ miniHint: String(localized: "Lower limit of the Sensitivity Ratio."),
|
|
|
verboseHint:
|
|
|
VStack(alignment: .leading, spacing: 10) {
|
|
|
Text("Default: 70%").bold()
|
|
|
Text(
|
|
|
- "Autosens Min sets the minimum Autosens Ratio used by Autosens, Dynamic ISF, and Sigmoid Formula."
|
|
|
+ "Autosens Min sets the minimum Sensitivity Ratio used by Autosens, Dynamic ISF, and Sigmoid Formula."
|
|
|
)
|
|
|
Text(
|
|
|
- "The Autosens Ratio is used to calculate the amount of adjustment needed to basal rates, ISF, and CR."
|
|
|
+ "The Sensitivity Ratio is used to calculate the amount of adjustment needed to basal rates and ISF."
|
|
|
)
|
|
|
Text(
|
|
|
- "Tip: Decreasing this value allows automatic adjustments of basal rates to be lower, ISF to be higher, and CR to be higher."
|
|
|
+ "Tip: Decreasing this value allows automatic adjustments of basal rates to be lower and ISF to be higher."
|
|
|
)
|
|
|
}
|
|
|
)
|
|
|
@@ -201,13 +201,13 @@ extension AutosensSettings {
|
|
|
units: state.units,
|
|
|
type: .boolean,
|
|
|
label: String(localized: "Rewind Resets Autosens", comment: "Rewind Resets Autosens"),
|
|
|
- miniHint: String(localized: "Pump rewind initiates a reset in Autosens Ratio."),
|
|
|
+ miniHint: String(localized: "Pump rewind initiates a reset in Sensitivity Ratio."),
|
|
|
verboseHint: VStack(alignment: .leading, spacing: 5) {
|
|
|
Text("Default: ON").bold()
|
|
|
Text("Medtronic and Dana Users Only").bold()
|
|
|
VStack(alignment: .leading, spacing: 10) {
|
|
|
Text(
|
|
|
- "This feature resets the Autosens Ratio to neutral when you rewind your pump on the assumption that this corresponds to a site change."
|
|
|
+ "This feature resets the Sensitivity Ratio to neutral when you rewind your pump on the assumption that this corresponds to a site change."
|
|
|
)
|
|
|
Text(
|
|
|
"Autosens will begin learning sensitivity anew from the time of the rewind, which may take up to 6 hours."
|